      Self-actuated Fire Extinguishing Equ…

      Home > Products > Self-actuated Fire Extinguishing Equ…

      Self-actuated Fire Extinguishing Equipment for Temperature Used Fire Detect Tube

      Back

      Product Overview

      Product Description:

      Self-actuated fire extinguishing equipment for temperature used fire detect tube was a new developed fixed but non-inductive temperature self-actuated small equipment in recentyears. Fire detection tube is a special plastic tube, which serves as theoriginal detection and extinguishing agent pipes, and was arranged in or on theprotecting…

      (If you are interested in our products, please click to view contact details)

      Share:
      • Introduction
      • Download

      Product Description:

      Self-actuated fire extinguishing equipment for temperature used fire detect tube was a new developed fixed but non-inductive temperature self-actuated small equipment in recentyears. Fire detection tube is a special plastic tube, which serves as theoriginal detection and extinguishing agent pipes, and was arranged in or on theprotecting space inside the device. when the protected object was on fire inone place, and with temperature reaches 170 ± 10℃,the fire detecting tube will startfire extinguisher container valves, then jet the fire extinguishing agent atthe broken place so as to implement the fire (named directtype), or jet the fire extinguishing along the tube (named indirect type). Self-actuated fire extinguishing equipment suit for small-volumedspace or huge space with airtight and small-volumed equipments in it.  As a new product, self-actuated fireextinguishing equipment for temperature used fire detect tube has effectivelysolved the problem---the fire extinguishing for small butdangerous space or equipment, like power distribution cabinet, communications cabinets, cable tray.

      Performance parameters:

      it is applicable at atemperature of 0℃~50℃;

      The gas (agent) used for CO2 fire extinguishing equipmentis from theatmosphere (made from air separation), and has no bad influence on theenvironment;

      Thegas (agent) used for HFC-227ea fire extinguishingequipment is colorless, tasteless, clean, low toxicity, and it has noresidue after fire, has no damage to the atmospheric ozone layer, is an environmentallyfriendly fire extinguishing agent.

      Technical characteristics:

      Nospecial need for fire detection control device, as it can automatically detect、start the fire extinguishing system, and implement the fireextinguishing. 

      Fire detecting tube reacts rapidly and can effectively put out thefire in the bud;

      No need for power, as it isn’t restricted by factors such as powersupply.

      No falsespray caused by bad environment factors such as oil, dust, smoke.

      Has no limitation ofprotective space, fire detecting tube get into various small and complex space;

      Simple Installation, and do not need special cyliders;

      Strong pertinence and effectiveness of fire extinguishing. The devicewas changed from the traditional protection for large enclosed space to varioussmall enclosed space. Especially suit for small but dangerous space or equipment.

      Safe and environmentally friendly. The device nearly has no influencetowards the command staff at the scene because it releases fire extinguishingagent in a variety of small enclosed space, thus minimize the damage and needno emergency evacuation. At the same time, it improves the utilization、saves the investment and reduces secondarypollution;

      Suit for equipments and sites which are unattended but need strongprotection.

      Places for Application:

      Compilation Basis

      GB50193-2010 Code of Design for CO2 FireExtinguishing System; GB50370-2005 Code of Design for GasFire Extinguishing System; GB50347-2004  Code of Designfor Dry powder fireextinguishingsystem;

      • Case Introduction

      Contact

      Us

      日韩激情无码一级毛片软件,9在线无码成人毛片视频免费,A级毛片无码免费真人久久久,亚洲高清AⅤ毛片 (function(){ var bp = document.createElement('script'); var curProtocol = window.location.protocol.split(':')[0]; if (curProtocol === 'https') { bp.src = 'https://zz.bdstatic.com/linksubmit/push.js'; } else { bp.src = 'http://push.zhanzhang.baidu.com/push.js'; } var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(bp, s); })();